M sensor
Self-powered Over-pressure Detection Sensor
A sensor that sends a signal on its own when pipe pressure exceeds the set value
When a pressure pipe reaches or exceeds the set pressure, that pressure moves the sensor, which generates power and sends a signal. Models are chosen according to operating pressure, and with no batteries or wiring, it can be installed at any point on the pipe.
- PowerSelf-powered (no battery)
- Dust · water protectionIP57
- Transmission rangeapprox. 100 m (open field)
- Detection pressure10 bar (20 · 30 bar: prototypes, not yet on sale)
01How it works
- Pressure rise
Due to a fault or mis-operation, pipe pressure rises above the normal pressure.
- Kinetic energy → electricity
Movement caused by the pressure generates power.
- RF transmission
Exceeding the set pressure is sent as a signal.
- Real-time monitoring
The location is identified and responded to.
02Features
A 10 bar model is supplied according to operating pressure, and 20 · 30 bar models have been developed as prototypes and are not yet on sale.
Installed at any point on the pipe.
Suitable for industrial site environments.
Instantly reports pressure rises to prevent explosions and failures early.
03System configuration
Over-pressure Detection Sensor 10 barMWSOP-100
RepeaterMWSR2-900 · Optional
Signal MonitorMWSM-700
PC monitoringSensor location · detection history
Text alertsManager's mobile phoneRanges are based on open field with no obstacles. Each added repeater extends the range by approx. 1 km.
04Specifications

Over-pressure Detection Sensor 10 bar
Model MWSOP-100
| Detection pressure | 10 bar |
|---|---|
| Size | W55 × D34 × H151 mm |
| Frequency | 920.700 MHz (FSK) |
| Antenna | Internal antenna |
| Transmission range | approx. 100 m (open field) |
| Power | Self-powered (no battery) |
| Dust · water protection | IP57 |
Over-pressure Detection Sensor 20 bar
Model MWSOP-200 Prototype (not yet on sale)
| Detection pressure | 20 bar |
|---|---|
| Size | W154 × D35 × H100 mm |
| Frequency | 920.700 MHz (FSK) |
| Antenna | Internal antenna |
| Transmission range | approx. 100 m (open field) |
| Power | Self-powered (no battery) |
| Dust · water protection | IP57 |
Over-pressure Detection Sensor 30 bar
Model MWSOP-300 Prototype (not yet on sale)
| Detection pressure | 30 bar |
|---|---|
| Size | W154 × D35 × H100 mm |
| Frequency | 920.700 MHz (FSK) |
| Antenna | Internal antenna |
| Transmission range | approx. 100 m (open field) |
| Power | Self-powered (no battery) |
| Dust · water protection | IP57 |
Receiving · monitoring devices used together

Repeater
Model MWSR2-900
| Size | W115 × D115 × H30 mm |
|---|---|
| Weight | 167 g |
| Frequency | 920.7 / 447.9 MHz (FSK) |
| Antenna | External antenna × 2 |
| Tx/Rx range | approx. 1 km (open field) |
| Range extension | +approx. 1 km (open field) |
| Display | FND 3-digit, LED (Rx · Tx · Power) |
| Power | DC 12 V 1 A adapter |

Signal Monitor
Model MWSM-700
| Size | W258 × D107 × H34 mm |
|---|---|
| Weight | 497 g |
| Frequency | 920.7 / 447.9 MHz (FSK) |
| Antenna | External antenna × 2 |
| Reception range | approx. 1 km (open field) |
| ID registration | max. 999 |
| Signal storage | Up to 10 overlapping signals |
| Display | FND 5-digit LED |
| External terminals | RS-485, beacon light, speaker, power |
| Power | DC 12 V 1 A adapter |
Specifications are subject to change without notice for performance improvement.
05Applications
Monitoring for exceeding normal pressure
Monitoring process pipe abnormalities
Early warning of abnormal equipment pressure
High-pressure line monitoring
Developed in 2023.
Installation sites
06Certifications · patents
07Materials · videos
08FAQ
QAt what pressure does it operate?
The pressures most commonly used are 10 · 20 · 30 bar. We currently supply the 10 bar model (MWSOP-100) ; 20 bar · 30 bar models are at the prototype stage (not yet on sale). The YouTube demo shows that it also operates at 5 bar. Let us know the pressure you need and we will review it.
QDoes it continuously display the pressure value?
This is a switch-type sensor that reports whether the set pressure has been exceeded. If continuous pressure measurement is required, it is configured together with a separate measuring instrument.
QCan it be monitored together with other sensors?
Since it uses the same 920.7 MHz signal, it is registered on the Signal Monitor and PC monitoring together with fire, valve and door sensors.
CONTACT MPIA
Self-powered Over-pressure Detection Sensor
A sensor that sends a signal on its own when pipe pressure exceeds the set value