Extra-high-voltage switchgear busbar fire detection
Fixed-temperature Fire Detection Sensors are attached to busbars, terminals and cables, and door sensors to panel doors, monitored via the Signal Monitor and monitoring program.

M sensor
Self-powered Fixed-temperature Fire Detection Sensor Self-powered Valve Open/Close Detection Sensor Self-powered Door Open/Close Detection Sensor Self-powered Object Movement Detection Sensor Self-powered Over-pressure Detection SensorM switch
Self-powered Wireless Switch SystemM call
Self-powered Emergency Bell System Guest Pager SystemMonitoring Systems
Signal Monitor System Sensor Hub · Smart Safety Alert Web & PC Monitoring SystemEco Products
DPF Fuel Injection Actuator Thermoelectric Dehumidifier / Panel CoolerPower Safety Platforms
GIS Substation Power Safety Platform Extra-high-voltage Switchgear Power Safety Platform Distribution Panel Power Safety Platform Cable Joint Power Safety Platform Data Center & ESS Power Safety PlatformEmergency Safety Platforms
Emergency Call Device Platform Emergency Bell Monitoring Platform Wireless Call Platform Device Control Platform Smart Safety Alert Platform Field CasesPower Safety Platforms
A disaster monitoring system that monitors the temperature, doors and emergencies of switchgear using self-powered sensors
In the LBS, MOF/PT and VCB/CT panels of extra-high-voltage switchgear, overheating of busbars, terminals and cables leads to fires.
Sensors must be attached inside panels where wiring is difficult to give advance warning of abnormal signs.
Temperature sensor80 ℃ alarm
Door sensorPanel opening
Emergency bellEmergency notification
RepeaterMWSR2-900
Signal MonitorMWSM-700
PC monitoringSensor location · detection history
Text alertsManager's mobile phoneRanges are based on open field with no obstacles. Each added repeater extends the range by approx. 1 km.
Busbar fire detection 3 · switchboard door 1 · emergency bell 1
Busbar fire detection 3 · switchboard door 1 · beacon light 1
Terminal · cable fire detection 4 · switchboard door 1
Repeaters 2 · Signal Monitor (PC 485 link) 1 · monitoring program · text messages

Model MWSF-100 (Busbar)
| Size | W77 × D56 × H140 mm |
|---|---|
| Weight | 200 g |
| Frequency | 920.700 MHz (FSK) |
| Transmission range | approx. 100 m (open field) |
| Operating temperature | approx. 75 – 85 ℃ or above |
| Power | Self-powered (no battery) |
| Dust · water protection | IP57 |

Model MWSR2-900
| Size | W115 × D115 × H30 mm |
|---|---|
| Weight | 167 g |
| Frequency | 920.7 / 447.9 MHz (FSK) |
| Antenna | External antenna × 2 |
| Tx/Rx range | approx. 1 km (open field) |
| Range extension | +approx. 1 km (open field) |
| Display | FND 3-digit, LED (Rx · Tx · Power) |
| Power | DC 12 V 1 A adapter |

Model MWSM-700
| Size | W258 × D107 × H34 mm |
|---|---|
| Weight | 497 g |
| Frequency | 920.7 / 447.9 MHz (FSK) |
| Antenna | External antenna × 2 |
| Reception range | approx. 1 km (open field) |
| ID registration | max. 999 |
| Signal storage | Up to 10 overlapping signals |
| Display | FND 5-digit LED |
| External terminals | RS-485, beacon light, speaker, power |
| Power | DC 12 V 1 A adapter |

Model —
| Operating environment | Runs on an on-site PC |
|---|---|
| Map | MAP layout (sensor location check) |
| Sensor display | Icon for each self-powered sensor |
| History management | Detection history saved |
| Protocol | RS485 |
| Port | RS485 to USB cable |

Model —
| Operating environment | Internet-connected PC with the monitoring program installed |
|---|---|
| ID registration | Phone number registration |
| Message text | Edit · delete beyond the default text |
| History management | Text message history management |
| Protocol | Internet-based |
Fixed-temperature Fire Detection Sensors are attached to busbars, terminals and cables, and door sensors to panel doors, monitored via the Signal Monitor and monitoring program.

Sensors attached at overheating points inside panels without wiring
Door openings and emergencies monitored on the same screen
Text alerts can be added after installation if needed
CONTACT MPIA
Extra-high-voltage Switchgear Power Safety Platform
A disaster monitoring system that monitors the temperature, doors and emergencies of switchgear using self-powered sensors